Pipeline Crawler Range |
PIPELINE CRAWLERS • PORTABLE X-RAY BETATRON • DIGITAL RADIOGRAPHY
For over 40 years, JME have manufactured, and been regarded as a world leader in high-quality Pipelines Crawlers. Today the CR2 Range of Pipeline Crawlers have been in the market for over 10 years, providing high-quality solutions in field proven environments. This is why when considering NDT inspection of pipelines, JME CR2 Pipeline Crawlers are the optimal choice for Radiographic Inspection of Circumferential Pipeline Welds.
JME X-Ray Pipeline Crawlers for Pipeline Weld Inspection
JME CR2 Pipeline Crawlers are remotely controlled internal X-Ray systems designed for the Radiographic Inspection of circumferential welds in pipelines. The Pipeline Crawler travels inside the pipeline and positions a panoramic X-Ray source centrally at each weld.
A Single-Wall-Single-Image (SWSI) radiograph can then be captured around the full circumference of the weld using film, Computed Radiography (CR) or Digital Radiography (DR/RTR) such as the JME DXB:1.
Designed and manufactured for demanding NDT applications, the JME CR2 Range supports pipeline diameters from 5.5" to 72" and has been developed continuously since its initial release more than 40 years ago in 1986.
- Pipe diameter range: approximately 5.5"–70“ (*72“ upon request)
- Inspection method: Internal Panoramic (360° X-ray radiography)
- Typical application: Circumferential pipeline / butt weld inspection
- Imaging: Film, CR or DR / RTR
- Applications: Onshore, Offshore and Pipeline Construction Environments
- Power: Self Powered - Battery Power (48V – 6CR2, 120V - 10/24CR2)
- Control: Remotely operated from outside the pipeline using magnetic control or RF – Wireless Control.
FOR MORE INFORMATION
Contact JME Advanced Inspection Systems on +44(0)1502 500969 or use our Contact Form >
DOWNLOAD DATASHEET
CRAWLER RANGE
frequently asked questions
Why use an X-ray crawler for pipeline inspection?
JME CR2 crawlers are engineered for repeated field operation and use corrosion-resistant materials and High grade industrial electronic components for operation in demanding environments.
X-Ray crawlers are particularly suited to radiography during pipeline construction because they allow the radiation source to be positioned internally, reducing shot time and improving “weld per day” productivity:
Potential operational advantages include:
- Panoramic inspection of the full weld circumference
(SWSI radiography from an internally positioned source) - Reduced need to reposition an external X-ray generator
– Improving Speed of image and deployment. - Repeatable positioning at successive pipeline welds
- Compatibility with film, CR and digital radiography
- Remote crawler control from outside the pipe, improving safety, workflow, and reducing risk.
- High-production inspection workflows
- Suitability for onshore and offshore pipeline projects
- Extensive temperature / operational range from -20°C - + 70°C
Which X-ray pipeline crawler do I need?
The correct Pipeline Crawler is determined primarily by:
- Pipeline - Internal Diameter (ID) and Wall Thickness (W/T) – Or Pipe Schedule (SCH).
- X-Ray Penetration Required - X-Ray output (kV / mA)
- Pipeline gradient and Site conditions
- Film, CR or DR imaging method
| JME 6:CR2 | JME 10:CR2 | JME 24:CR2 |
| Pipeline ID/ND diameter range 5.5” to 18” (140mm to 457mm) / 6” SCH120 Weight (Excluding X-Ray tube) 9Ah Battery – 71lbs (32 Kg) 15Ah Battery – 90lbs (41 Kg) Length (Excluding X-Ray tube) 1500mm (59″) (including recovery ring) X-Ray tube output options JMXT 180, ICM CP160CR/1802 Power source Sealed Lead Acid Batteries 48V (9Ah or 15Ah) Battery capacity 9Ah / 15Ah Depending on pipe size requirements Travel speed Up to 12metres (40ft) per minute Maximum angle of climb (Optimum Conditions) 25° from horizontal Operating temperature range -20°C to +70°C |
Pipeline ID diameter range 9.5” to 48” (240mm to 1220mm)Weight (Excluding X-Ray tube) 286.6lbs (130Kg) Length (Excluding X-Ray tube) 1717mm (246mm Recovery Ring) X-Ray tube output options 160kV - 360kV Power source Sealed Lead Acid Batteries - 120V Battery capacity 24Ah Average exposures per battery pack 204 @30sec Travel speed Up to 22 metres per minute Maximum angle of climb (Optimum Conditions) ≤20° / 36.4% Operating temperature range -20°C* to +70°C *For lower operating temperature range JME.
JME 10:CR2:S MODEL Weight |
Pipeline ID/ND diameter range 22″ to 72″ (558mm to 1829mm)Weight (Excluding X-Ray tube) 24Ah = 370 lbs (167Kg) 34Ah = 441 lbs (200Kg) Length (Excluding X-Ray tube) 51.1″ - 60.4″ (1300-1535mm) (Depending upon configuration) X-Ray tube output options 160kV – 360kV Power source Sealed Lead Acid Batteries (120v) Battery capacity 34Ah or 24Ah Depending on pipe size requirements Travel speed Up to 0.39m/sec max Wheels Contoured High Traction Rubber Maximum angle of climb (Optimum Conditions) ± 30° Operating temperature range -40° to +70° C (-20° upon request) |
For Small-Diameter Pipelines
The JME 6:CR2 is designed for pipe diameters from approximately 5.5" to 18" (140–457 mm) ID (Internal Diameter)
It can travel at up to 12 metres per minute under suitable conditions and provides mean positioning accuracy of ±5 mm.
For Medium and Large Pipeline Construction
The JME 10:CR2 supports internal pipe diameters from approximately 9.5" to 48" (240–1220 mm) as standard, and upto 60” upon request. Operating with a range of X-Ray generators COMET, Balteau and Teledyne ICM.
For Large-Diameter Pipelines
The JME 24:CR2 is designed for approximately 22" to 72" (558–1829mm) internal diameter pipelines and can be configured with X-Ray generators from manufacturers including COMET, Balteau and Teledyne ICM.
Not sure which Crawler fits your application?
Send JME your pipe diameter, wall thickness and inspection requirements and our team can recommend an appropriate crawler and X-Ray source configuration.
Can pipeline crawlers be used with digital radiography?
Yes.
JME CR2 Pipeline Crawlers can form part of Film, Computed Radiography and Digital Radiography workflows.
When combined with JME's DXB Digital Radiography system, Pipeline Inspection teams can capture and review radiographic images digitally rather than relying solely on conventional film processing.
On one 16" pipeline project in Carlsbad, New Mexico, two JME 10CR2 Crawlers were deployed with COMET 300P X-Ray Tubes and JME DXB Digital Radiography Systems.
The project involved 1,500 welds over 14 days, with the inspection team completing approximately 90–110 welds per day. The project was performed to API 1104 requirements and achieved a verified transition time of approximately 4.5 minutes from one weld to the next.
How are JME Pipeline Crawlers controlled?
JME CR2 Crawler systems can be controlled externally while operating inside the pipeline.
JME's magnetic control system allows commands to be transmitted from outside the pipe without trailing control cables and can be used stand alone or in conjunction with a JME Remote Handset:
- Depending on crawler configuration, operators can command functions including:
- Drive – Start / Stop / Direction and Speed.
- X-Ray – Start / Stop / Pause.
- Radiographic exposure parameters (wireless control - inc. Kv/mA adjustment).
- Weld positioning
- System configuration
- Operational monitoring
The JME CR2 Remote Handset provides an additional interface for configuring and monitoring crawler operation.
Does a JME Pipeline Crawler require a Control Isotope?
JME has developed magnetic and non-isotope control and tracking options designed to reduce reliance on traditional isotope-based crawler control methods.
The JME Magnetope system allows crawler commands to be transmitted from outside the pipeline using magnetic control.
Crawler location and direction can be controlled by the Magnetrope, or wirelessly using the JME Remote Handset.
This can be particularly valuable where transportation or use of low-activity isotopes creates additional regulatory or logistical requirements as the magnetope / Handset combination has also been used to replace the need for isotope in Offshore / Barge applications where historically the CWC (concrete weight coat) require the need for isotope control / Positioning.
Are X-Ray Pipeline Crawlers suitable for Offshore Inspection?
Yes. JME CR2 equipment has been used for offshore pipeline construction and barge-based inspection projects as well as conventional onshore pipeline spreads.
REQUEST QUOTATION
JME PIPELINE CRAWLER
AND ACCESSORIES
Download and complete the
PDF quotation request form.
JME PIPELINE CRAWLER Remote HANDSET
JME’s unique handset, with 4.3” touchscreen and multi-language support, allows external control and monitoring of the crawler whilst operating in the pipe.
This device allows the user to set up and configure the entire system, including X-ray tube/Gamma projector prior to placing it in the pipe. It is also capable of providing real time data from the system whilst in operation. It encorporates safety overide and recovery features, making the new crawler systems more intuitive than ever.
PRODUCT CATALOGUE
2026 EDITION
JME's updated 2026 Product Catalogue is now available for download. Fully updated with our new products and refreshed information.
PDF Download: 4.6mb
COMPANY
LOCATION
JME Ltd.
Electron House
Old Nelson Street
Lowestoft, Suffolk
NR32 1EQ
UNITED KINGDOM
PROUDLY SUPPLYING THE NDT INDUSTRY FOR OVER 40 YEARS
Company Registration No 2056386 - Registered in England & Wales
VAT No GB 443 0172 87 © JME LTD - 1986-2026. All Rights Reserved.