HOME  •  CONTACT  •  ABOUT  •  NEWS  •  CAREERS

JME BETATRON RANGE | 

PIPELINE CRAWLERS • PORTABLE X-RAY BETATRON • DIGITAL RADIOGRAPHY

JME Portable X-Ray Betatron systems are a range of compact circular electron accelerators producing a high energy directional X-Ray beam.

JME Betatron systems are simple to operate and maintain as they contain no moving parts or cooling liquids, which aids simple maintenance, and ensuring minimal down-time.

They are capable of producing radiographs of very high contrast, sensitivity and resolution, allowing operators to meet the tightest inspection standards including ISO 17636-1, iso 17636-2. ASME and more.

JME offer 4 NDT systems within the Betatron range each with a different maximum output energy, the outputs are 2.5, 6, 7.5 and 9MeV (Mega Electron Volts).

The energy output on all systems is variable within 0.1 MeV increments enabling optimisation of contrast, image quality and safety.

Energy adjustment allows flexibility to work within image quality enhancements, safe working zones (limiting energy to reduce exclusion zones), and the ability to deploy Betatrons for a much greater range of both, less dense, and dense heavy wall objects. Allowing improved flexibility of inspection operations and services, maximising end user deployment possibilities and overall return on investment.

FOR MORE INFORMATION

Contact JME Advanced Inspection Systems on +44(0)1502 500969 or use our Contact Form >

frequently asked questions

What is a Betatron used for?

A Betatron produces high-energy X-rays for non-destructive inspection / testing (NDT) of thick or dense materials. Typical applications include heavy-section welds, castings, valves, pressure vessels and reinforced concrete structures.

SEE INDUSTRY SECTORS >

VIEW CASE STUDIES >

Which JME Betatron should I choose?

JME offer Betatrons with maximum energies of 2.5, 6, 7.5 and 9 MeV. The most suitable model depends on material thickness, required image quality, exposure time and deployment conditions. Adjustable energy allows the output to be matched to the inspection, and JME can help select a suitable configuration and system type.

 

JME PXB 2.5MeV JME PXB 6MeV JME PXB 7.5MeV JME PXB 9MeV
Peak X-Ray Output
2.5MeV
Dose rate @ 1m
>0.7R/minute
Focal Spot Size
0.2 x 2mm
Duty Cycle Radiation Beam
75% per hour
Beam Coverage
350 x 350mm @1m (13.8" x 13.8" @ 39.8)
Radiographic Sensitivity
Down to 1%
Supply Voltage
Single-phase, 110V or 220V, 50/60Hz
Adjustment range of energy
1.0 to 2.5MeV in 0.1MeV increments
Power Consumption
1.0kW (4.5A @220V, 9A @ 110V)
Peak X-Ray Output
2 to 6MeV
Dose rate @ 1m
>3R/minute
Focal Spot Size
0.3 x 3mm
Duty Cycle Radiation Beam
75% per hour
Beam Coverage
250 x 250mm @1m (9.8" x 9.8" @ 39.4")
Radiographic Sensitivity
Down to 1%
Supply Voltage
Single-phase, 110V or 220V, 50/60Hz
Adjustment range of energy
2.0 to 6MeV in 0.1MeV increments
Power Consumption
2.0kW (9A @220V, 18A @ 110V)   

 

Single or Three Phase available upon request

Peak X-Ray Output
2 to 7.5MeV
Dose rate @ 1m
>5R/minute
Focal Spot Size
0.3 x 3mm
Duty Cycle Radiation Beam
75% per hour
Beam Coverage
250 x 250mm @1m (9.8" x 9.8" @ 39.4")
Radiographic Sensitivity
Down to 1%
Supply Voltage
Single-phase, 110V or 220V, 50/60Hz
Adjustment range of energy
2.0 to 7.5MeV in 0.1MeV increments
Power Consumption
3.0kW (13.6A @220V, 27A @ 110V)   

 

Single or Three Phase available upon request

Peak X-Ray Output
2 to 9MeV
Dose rate @ 1m
>20R/minute
Focal Spot Size
0.3 x 3mm
Duty Cycle Radiation Beam
50% per hour
Beam Coverage
250 x 250mm @1m (9.8" x 9.8" @ 39.4")
Radiographic Sensitivity
Down to 1%
Supply Voltage
3-phase (220V/380V), 50/60Hz
Adjustment range of energy
2.0 to 9MeV in 0.1MeV increments
Power Consumption
5.0kW (7.6A per phase)
How much material can a JME Betatron penetrate?

Penetration depends on the model, material and inspection setup. For example, JME recommends the PXB 7.5 MeV for radiographic testing of steel welds and castings between 50–300 mm thick. Achievable results depend on geometry, detector or film selection, exposure time and the required inspection standard.

Can a Betatron be used on site?

Yes. JME Betatrons are designed for transport and assembly at inspection locations, including fabrication workshops and external sites (In-field radiography). Power and handling requirements vary by model with the 2.5/6/7.5 Mev systems being mains or battery powered. Each deployment requires suitable access and a planned radiation-controlled area. Wireless control options provide additional flexibility for remote operation.

How does a Betatron compare with Cobalt-60 radiography?

A Betatron generates X-rays electrically, providing adjustable energy without radioactive-isotope decay or periodic source replacement. For suitable applications, it can offer improved image quality and shorter exposures compared with Cobalt-60. The choice depends on material thickness, access, and inspection requirements.

Need help selecting a Betatron?

Contact JME on +44 (0)1502 500969 or sales@jme.co.uk with your component details and inspection requirements.

DOWNLOAD DATASHEET

BETATRON RANGE

REQUEST QUOTATION
JME PORTABLE
X-RAY BETATRON

Download and complete the
PDF quotation request form.

PRODUCT CATALOGUE
2026 EDITION

JME's updated 2026 Product Catalogue is now available for download. Fully updated with our new products and refreshed information.

PDF Download: 4.6mb

CONTACT

+44 (0)1502 500969

LOCATION

JME Ltd.
Electron House
Old Nelson Street

Lowestoft, Suffolk
NR32 1EQ
UNITED KINGDOM

PROUDLY SUPPLYING THE NDT INDUSTRY FOR OVER 40 YEARS

Company Registration No 2056386 - Registered in England & Wales
VAT No GB 443 0172 87 © JME LTD - 1986-2026. All Rights Reserved.

 
JME Ltd. reserves the right not to be responsible for the correctness of information supplied within this website. This includes all liability claims relating to usability of products for certain uses and technical specifications supplied.
Telephone calls are recorded for monitoring and quality purposes.