BALTEAU | PORTABLE X-RAY TUBE RANGE
PIPELINE CRAWLERS • PORTABLE X-RAY BETATRON • DIGITAL RADIOGRAPHY
The generator is driven by an electronic circuit board (the power components are cooled by forced air). Components can be readily installed in the crawler body and connected to its general circuitry. Any DC voltages within the range of 72 to 130v can be selected and applied to the generator.
An exclusive feature allows generator to operate at constant kV and mA no matter of the battery cycles. This feature ensures a stable dose output and guarantees image quality consistency all along the exposure time.
This specific process, is also improving the operating possibilities of the battery pack. Indeed many more exposures can be taken. This process improves the battery lifetime thanks to a better management of discharge cycles.
TECHNICAL SPECIFICATION
High voltage range | 112-160kV |
Approx. tube output | 3mA |
Beam angle | 360° x 40° |
Focal spot size (IEC336) | 4 x 0.9 |
Max. current | 4.5A |
Steel penetration at max (*) | 12.5mm |
Working temperature | – 10 to + 40°C |
Inherent filtration | 7mm AI |
Anode cooling type | Air |
Duty cycle | 50% at 35°C |
Insulation | SF6 Gas |
Mains | 72 – 130V |
Weight (without rings) | 11Kg |
Tubehead | Glass |
Control Unit | CF3 |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
The generator is driven by an electronic circuit board (the power components are cooled by forced air). Components can be readily installed in the crawler body and connected to its general circuitry. Any DC voltages within the range of 72 to 130v can be selected and applied to the generator.
An exclusive feature allows generator to operate at constant kV and mA no matter of the battery cycles. This feature ensures a stable dose output and guarantees image quality consistency all along the exposure time.
This specific process, is also improving not only the operating possibilities of the battery pack, thus many more exposures can be taken before the batteries are discharged, but also it improves the battery lifetime by a better management of discharge cycles.
TECHNICAL SPECIFICATION
High voltage range | 140-200kV |
Approx. tube output | 3mA |
Beam angle | 360° x 45° |
Focal spot size (IEC336) | 4 x 1.2 |
Max. current | 9A |
Steel penetration at max (*) | 24mm |
Working temperature | – 10 to + 40°C |
Inherent filtration | 9mm AI |
Anode cooling type | Air |
Duty cycle | 50% at 35°C |
Insulation | SF6 Gas |
Mains | 72 – 130V |
Weight (without rings) | 20Kg |
Tubehead | Glass |
Control Unit | CF3 |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
The generator is driven by an electronic circuit board (the power components are cooled by forced air). Components can be readily installed in the crawler body and connected to its general circuitry. Any DC voltages within the range of 72 to 130 V can be selected and applied to the generator.
An exclusive feature allows generator to operate at constant kV and mA no matter of the battery cycles. This feature ensures a stable dose output and guarentees image quality consistency all along the exposure time.
This specific process is also improving not only tje operating possibilities of the battery pack, thus many more exposures can be taken before the batteries are discharged, but also it improves the battery lifetime by a better management of discharge cycles.
TECHNICAL SPECIFICATION
High voltage range | 150-300kV |
Approx. tube output | 3mA |
Beam angle | 360° x 45° |
Focal spot size (IEC336) | 4 x 1.3 |
Max. current | 12A |
Steel penetration at max (*) | 44mm |
Working temperature | – 10 to + 40°C |
Inherent filtration | 9mm AI |
Anode cooling type | Air |
Duty cycle | 50% at 35°C |
Insulation | SF6 Gas |
Mains | 72 – 130V |
Weight (without rings) | 23.5Kg |
Tubehead | Glass |
Control Unit | CF3 |
* FFD= 700mm/Film Carestream Industrex AA400/D=2.0/t=10min.
FOR MORE INFORMATION
Contact JME Advanced Inspection Systems on +44(0)1502 500969 or use our Contact Form >
DOWNLOAD DATASHEET
REQUEST QUOTATION
BALTEAU
X-Ray Solutions
Please enquire using our contact form.
COMPANY
LOCATION
JME Ltd.
Electron House
Old Nelson Street
Lowestoft, Suffolk
NR32 1EQ
UNITED KINGDOM
PROUDLY SUPPLYING THE NDT INDUSTRY FOR OVER 35 YEARS
Company Registration No 2056386 - Registered in England & Wales