JME:PBU |
PIPELINE CRAWLERS • PORTABLE X-RAY BETATRON • DIGITAL RADIOGRAPHY
The JME:PBU provides a lightweight/mobile power solution for devices intended to run on 230V/16A.
Proven and tested with the JME 2.5meV (1kW) Betatron and COMET EVO/ECO range to provide over 1.5 hours of X-Ray time (900W). This will also power a 6/7.5MJ Betatron for more than a full duty cycle (45 minutes).
The PBU removes the need for flammable liquids on site for use with generators, reduces overall deployment weight, improves access to hard to reach and hazardous locations, while removing the need for maintenance and risk of unplanned break downs.
Enabling improved deployment with stable and clean power, producing no noise or environmental emissions the PBU is suited for: Powering pipeline crawler chargers, XRay tube run-in without loading the battery of the Pipeline Crawler’, Dark Room back up and Powering auxiliary operations such as DXB:1 system charging, and much more.
![]()
TECHNICAL SPECIFICATION
| OPERATING STATE: DISCHARGING | ||
|---|---|---|
| Output voltage | 230 VAC / 50 Hz | European grid standard |
| Rated power | 3.600 W / 16 A | RMS |
| 150% overload (5,400 W / 24 A) | Operation for >500 s possible | RMS |
| 200% overload (7,200 W / 32 A) | Operation for >50 s possible | RMS |
| 250% overload (9,000 W / 40 A) | Operation for >10 s possible | RMS |
| Peak Power | 18.000 W / 80 A | RMS |
| Maximum short-circuit current | 500 A (peak) | Peak |
| Maximum operating time (idle) | 150 h | |
| Line protection | 16 A – similar to „B16“ circuit breaker | |
| Permitted operating temperature | -20°C to 60°C | |
| OPERATING STATE: CHARGING | ||
| Input voltage | 120-240 VAC / 50-60 Hz | RMS |
| Rated power | 500-1.000 W / 4 A | Voltage independent current consumption/ RMS |
| Charge time | < 3h to 100% | At 230 VAC and 25°C ambient temperature |
| Permitted operating temperature | 0°C to 45°C | |
| GENERAL INFORMATION | ||
| Battery capacity | 2.074 Wh | |
| Weight | 20 kg | |
| Dimensions | 420 x 210 x 420 mm | |
| IP Class | IP54 | Water and dust proof |
| Protection class | Class II / double-insulated | According to IEC 61140 |
| Noise emission | < 10 dB(A) | Silent |
| Storage | > 3 years | |
| CONNECTIONS | ||
| Output socket | BS1363-2 (13 A) | |
| Output socket | Neutrik powerCON TRUE1® TOP® | |
| Load input | Neutrik powerCON TRUE1® TOP® | Incl. charging cable |
| Input fuse | T5A L 250 V | |

TRANSPORT INFORMATION |
|
![]() |
TRANSPORT mode isolates all of the battery modules from each other, and the unit can be transported in accordance with SP188 The PBU has a modular structure, whereby each single battery module has an energy content of 86.4Wh. If the unit is going to be transported, it must be put into TRANSPORT mode. To do this, move the rotary switch all the way to the left to the padlock symbol, as shown in the illustration. This results in all the battery modules in the unit being separated from each other, and the cover of the PBU therefore constitutes packaging for individual battery modules with less than 100Wh. The unit may be transported in accordance with SP188 in this mode. |

FOR MORE INFORMATION
Contact JME Advanced Inspection Systems on +44(0)1502 500969 or use our Contact Form >
DOWNLOAD DATASHEET
COMPATIBLE PRODUCTS
EXTENDED WARRANTY
Despite JME providing full Warranty with all systems as per our terms and conditions, Extended Warranty is available on certain product ranges upon request. If this is of interest, please highlight this in communications with the JME Sales Team.
PRODUCT CATALOGUE
2025 EDITION
JME's updated 2025 Product Catalogue is now available for download. Fully updated with our new products and refreshed information.
PDF Download: 4.6mb
COMPANY
LOCATION
JME Ltd.
Electron House
Old Nelson Street
Lowestoft, Suffolk
NR32 1EQ
UNITED KINGDOM
PROUDLY SUPPLYING THE NDT INDUSTRY FOR OVER 35 YEARS
Company Registration No 2056386 - Registered in England & Wales
VAT No GB 443 0172 87 © JME LTD - 1986-2024. All Rights Reserved.