DXB:1 |
PIPELINE CRAWLERS • PORTABLE X-RAY BETATRON • DIGITAL RADIOGRAPHY
JME would like to present our newest product, the DXB:1 Digital X-Ray Buggy; designed to produce high-quality panoramic digital radiographs of circumferential welds in applications such as new pipelines. As a versatile and configurable system, it can also be utilised for use in various non-pipeline applications, such as the inspection of tank walls or other ferrous metal structures.
This digital system is a replacement for traditional film radiography; so no more chemical
processing, dark rooms, or flaws associated with conventional radiography. The DXB:1 includes a high-definition digital panel for instant verification of image quality and system settings. Images are digitally stored, preventing the need for film storage and enabling a permanent record to be saved within the control tablet. These can be backed up via USB or using a Network connection, allowing the images to be sent to an o-site Radiographer seconds from acquisition.
JME’s DXB:1 system also communicates and integrates with our entire CR2 Pipeline Crawler
Range. This allows 2-way communication between the Pipeline Crawler and DXB:1, giving
configuration of key crawler parameters from the DXB:1 control tablet. This integration also allows commencement of inspection with the push of a single button. The DXB:1 operator is able to control, adjust and view the status of the CR2 crawler at all times during an inspection task.
With a rapid magnetic deployment system, the DXB:1 can be positioned by a single person in
less than a minute. The system is attached using permanent magnets, meaning in the event of a loss of power the unit will remain firmly attached to the pipe. This quick and efficient deployment dramatically increases productivity on-site. There is no need for welding bands to be deployed and relocated between each inspection which again greatly improves efficiency on-site.
DXB:1 SYSTEM FEATURES
- Deployed in seconds, no welding bands required
- Film replacement technology
- Wireless, No Cable Management
- Allows for ‘Cloud-based’ image inspection
- Fully integrated with crawler operation
- Integrated functionality with the CR2 Remote Handset Unit
- One-touch inspection
- Comprehensive safety interlocks
- Automatic back-up of images
- Digital storage of images locally or web-based
- Magnetic mounting
DXB:1 EXAMPLE IMAGE SEGMENT

View Larger Weld Image (opens in new tab - 1.2mb) >
Example of the exported, stiched, Diconde Images
produced by the DXB:1 Digital X-Ray System
DXB:1 RUGGED CONTROL TABLET

OVERALL SYSTEM SPECIFICATION
| Buggy Width | 220mm (8.7") |
|---|---|
| Pipeline Diameter | 254mm (10”) |
| Average Scan Speed | Minimum: 15 mm/s Typical: 22 mm/s (including imaging time and movement between images) - Depending upon pipe schedule |
| Image Quality | Image quality class B acc. ISO19232-5, ISO 10893-7, ISO 17636-2 |
| Image Format | DICONDE compliant data export, via Ethernet or USB |
| System Weight | Buggy, Detector and Battery - < 44.1 lbs (< 20Kg) |
| Dimensions (mm) | Overall Package Kit - 687(L) x 528(W) x 552(H) (27" x 20.8" x 21.7") |
| Positioning | Manually positioned directly onto pipe cut-back with no bands |
| Operating Temperature | -20°C to +60°C |
| Power Consumption | <50W |
| Imaging X-Ray Energy | Up to 300kV |
| Image Storage Capacity | 500+ Images @ 36” pipe |
IMAGING
| Resolution | 100 µm |
|---|---|
| Technology | CMOS |
| Image area | Width: 100mm Length: up to 150mm per image (depending upon pipe diameter) |
| Image Stitching | Uses image feature matching algorithm |
CONTROL TABLET SPECIFICATIONS
| Display | 10.1” 10-point capacitive multi touch screen, high definition, daylight readable, Waterproof digitizer pen for improved ease of use |
|---|---|
| Certification | MIL-STD-810G certified at 180cm IP65 certified |
| Power Option | Li-ion 11.4 V, 4360 mAh - Comes with 2 battery types |
| Dimensions | 279(L) x 188(W) x 23.5(H) (11.0” x 7.4” x 0.93”) |
| Weight | Approx 2.64 lbs (1.19Kg) |
| Operating System | Windows© 11 Pro |
BUGGY POWER OPTIONS
| Battery Specifications (DeWalt Flexvolt) |
54V 2000mAh 54V 3000mAh 54V 4000mAh = 125 shots* (18” Pipe) *Average shots - dependent upon system settings |
|---|
CONTROL SYSTEM
| User Interface | Touch-screen display, with intuitive controls. Image viewing and assessment functions for on-site checking of acquired images prior to formal interpretation. |
|---|---|
| Image Acquisition | Automatic acquisition process, controlled by user. |
| Crawler Control | Full crawler control integration, to synchronise crawler operations and image acquisition. |
All specifications correct at time of upload
DXB:1 SOFTWARE SUITE
The DXB Software Suite allows for real-time X-Ray image acquisition, along with viewing, image processing and archiving of images. The Pipeline Crawler and X-Ray source settings can be controlled directly from within the software without the need for other control devices. X-Ray images are stored in DICONDE data format and saved to the current project, along with any additional photographs, notes, inspection date, time and GPS co-ordinates. Using the JME stitching algorithm, a single image can be viewed in real-time, with the full weld stitched upon completion of the weld acquisition.
DXB:1 PACKAGE CONTENTS
- DXB BUGGY
- 2X SPARE BATTERIES
- BATTERY CHARGER
- CONTROL TABLET
- 2X CONTROL TABLET SPARE BATTERIES
- CONTROL TABLET CHARGER
- RAID-1 CONFIGURED EXTERNAL USB HDD
- ASSORTMENT OF ARIELS, ADAPTERS AND IQI'S
- BOX OF CHARGING and DATA LEADS
- 3 MONTHS TRIAL DURR SOFTWARE
- ADDITIONAL DURR SOFTWARE PACKAGES and SPARES KIT UPON REQUEST

FOR MORE INFORMATION
Contact JME Advanced Inspection Systems on +44(0)1502 500969 or use our Contact Form >
Frequently Asked Questions
What is the JME DXB used for?
The DXB:1 Digital X-Ray Buggy produces digital radiographs of circumferential pipeline welds. It can also be configured for applications such as tank walls and other suitable ferrous structures.
Can the DXB work with my JME pipeline crawler?
The DXB integrates with JME’s CR2 Pipeline Crawler range. Two-way communication allows operators to adjust crawler settings, monitor status and coordinate inspection from the DXB control tablet. Contact JME to confirm compatibility with your equipment.
Does the DXB replace radiographic film?
Yes. Its digital detector removes the need for film processing and darkrooms. Operators can check acquired images on site before formal interpretation.
How is the DXB attached to the pipe?
Permanent magnets secure the buggy directly to the pipe cut-back, without welding bands. Therefore, the magnetic attachment remains effective if power is lost.
Can images be stored and reviewed remotely?
Yes. Images can be stored digitally and exported in Tiff, Jpeg or DICONDE format through USB or Ethernet, supporting backup, traceability and off-site review.
What X-ray energy can the DXB accommodate?
The DXB:1 supports X-ray energies up to 300 kV. This matches the current kV Limit for pipeline crawlers.
How quickly can the DXB be deployed?
The magnetic mounting system allows one person to position the DXB in less than a minute under suitable conditions. Actual setup time depends on access, pipe condition and site arrangements. There is a real world case study here >
Is the DXB battery-powered?
Yes. The buggy uses rechargeable DeWalt Flexvolt batteries, and the control tablet has its own battery supply as well as mains / vehicle charging and powering options.
How heavy is the DXB?
The combined weight of the buggy, detector and battery is less than 20 kg.
DOWNLOAD DATASHEET
PRODUCT CATALOGUE
2026 EDITION
JME's updated 2026 Product Catalogue is now available for download. Fully updated with our new products and refreshed information.
PDF Download: 4.6mb
COMPANY
LOCATION
JME Ltd.
Electron House
Old Nelson Street
Lowestoft, Suffolk
NR32 1EQ
UNITED KINGDOM
PROUDLY SUPPLYING THE NDT INDUSTRY FOR OVER 40 YEARS
Company Registration No 2056386 - Registered in England & Wales
VAT No GB 443 0172 87 © JME LTD - 1986-2026. All Rights Reserved.
